Sunpower Model SPS-S060-24 Series-jabasystem, 60W,

Sunpower Model SPS-S060-24 Series-jabasystem, 60W, Single Output, Green Mode Function. Please click on below picture to view complete specifications in PDF file of SPS-S060.

Sunpower Model SPS-S060-24

Sunpower Model SPS-S060-24

* Green mode design, no load < 0.5W

* High efficiency and high reliability

* Built in EMI filter, low ripple noise

* Over voltage protection: Shutdown and latch off

* Over load & short circuit protection: Hiccup mode

* 100% full load burn-in test

* -20 degrees Celsius ~ 70 degrees Celsius Operating temperature

* UL, cUL, TUV, CB, CE approved

Specifications:

Input Voltage: 88V~ 264VAC universal full range or 125V ~ 375VDC.

Input Frequency: 47 —–63Hz

Input Current: <1.6A@100V AC input, full load condition

Input Inrush Current: <30A@115V, <50A@230V AC input, Cold start at 25degrees Celsius ambient

Input Leakage Current: <0.75mA@264V AC input

 

Protection Over Voltage: Shutdown and latch off, recover after re-start up.

Protection Over Load & Short circuit: When power supply over 105%~150% max load or short circuit acted, power supply will go into hiccup mode and recover automatically after the fault is removed.

Elec. Char. Rise Time: <30mS

Elec. char. Hold Up Time: >60mS@230V, full load condition

Elec. Char. Setup Time: <1 Sec@100 ~ 240VAC

Elec. Char. Green Mode Function: Power consumption at no load<0.5W at 240VAC input.

 

Environmental Temperature Operating: -20~+ 70degrees Celsius; De-rating: 50 ~ 70degrees Celsius: 2.5% /degrees Celsius; Storage:-40~ +85degrees Celsius

Environmental Humidity Operating:20%~ 90% RH( non condensing) ; Storage: 10% ~ 95% RH ( non condensing )

 

Safety Withstand Voltage: I/P-O/P: 3KVAC, I/P-PE: 1.5KVAC, O/P-PE: 0.5KVAC,1 minute

Safety Isolation Resistance: I/P-O/P, I/P-PE. O/P-PE > 100Megaohm/500VDC at 25degrees Celsius/70 % RH

Safety Standard: UL60950-1 2nd, CSA C22.2 No. 60950-1-07 2nd, TUV EN 60950-1:2006+A11+A1+A12, IEC 60950-1: 2005+A1, approved

EMC EMI: EN 55022 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B. Compliance to EN61000-3-2 CLASS A, EN61000-3-3

EMC EMS: EN 55024 : EN 61000-4-2,3,4,5,6,8,11

 

M.T.B.F: 335K hours